Kilo-Watt Hour Meter
DIN-Rail Kilo-Watt Hour Meter
Be used both in 50Hz or 60Hz AC electricity networks.
Displayed on a horizontal positioned 5+1 impulse step type register.
Equipped with an SO contact for convenient monitoring with external equipment.
TECHNICAL PARAMETER
Conform to IEC 61036 Accuracy: class 1, 2
Frequency: 50/60Hz Single phase: 220-240V
Rated impulse voltage: Uimp 6KV-1.2/50µS
Power consumption: ≤1.5w/6VA per phase
Temperature range: -10°C¬-+50°C
Conform to IEC 61036 Accuracy: class 1, 2
Frequency: 50/60Hz Three phase: 3X100V, 3X380V
Rated impulse voltage: Uimp: 10KV-1.2/50µS
Power consumption: ≤2w / 10VA per phase
Temperature range: -10°C- +50°C
2. Connection parameters:
| Designation | Rating (Amps) | Pack Qty. | Cat. No. |
| Single Phase 4 module | 2.5(10)A | 1 | DS977-01A |
| 3(15)A | 1 | DS977-02A | |
| 5(30)A | 1 | DS977-03A | |
| 10(50)A | 1 | DS977-04A | |
| 15(90)A | 1 | DS977-05A | |
| 20(100)A | 1 | DS977-06A | |
| 5(40)A | 1 | DS977-07A | |
| 5(100)A | 1 | DS977-08A | |
| Three Phase 7 module | CTtype 1.5(10)A | 1 | DT977-01A |
| 3(6)A | 1 | DT977-02A | |
| Direct 5(30)A | 1 | DT977-03A | |
| 10(50)A | 1 | DT977-04A | |
| 15(90)A | 1 | DT977-05A | |
| 20(100)A | 1 | DT977-06A | |
| 5(40)A | 1 | DT977-07A | |
| 5(100)A | 1 | DT977-08A |
Kilo-watt Hour Meter
1. Specifications of Kilo-watt Hour Meter:
| Item NO. | BZ142-1 |
| Supply Voltage | AC24V/240V,50/60Hz |
| Dimensions | 48 X48 X 40mm |
| Time Range | 0~99,999.99 Hours |
| Installation mode | Inbuilt |
| Net weight | 50g |
This products is suitable for usage of house,
industry, Airconditioning, etc.
3. Accessories parts: BZ142-A Adapter 72 x 72, for BZ142-1.
DD282 Single Phase Kilo-watt Hour Meter (KWH)
1. Application of Kilo-watt Hour MeterDD282 single phase energy meter is induction meter which is applicable to measure the rated frequency 50Hz and power loss in electrified wire netting. All technical targets completely conform to IEC60521.
2. Specifications of Kilo-watt Hour Meter:
| Type | Accuracy (Class) | Rated Voltage (V) | Rated Current (A) | Overload Capacity | Starting Current | Insulation |
| DD282 | U | 220 | 2(4),2.5(10),3(6), 5(10),10(20),20(40), 30(60),40(80) | 200% Ib | 0.5% Ib | AC voltage 2kV for 1 minute impulse voltage 6kV |

DD862 Single Phase Kilo-watt Hour Meter (KWH)
1. Application of DD862 Single Phase Kilo-watt Hour Meter:DD862 Single Phase Energy Meter is induction meter which is appliable to measure the rated frequency 50Hz and power loss in electrified wire netting. The meter has novel design, rational structure and features of large overload, low power loss and long life etc. All technical targets completely conform to IEC60521.
2. Specifications of DD862 Single Phase Kilo-watt Hour Meter:
| Type | Accuracy (Class) | Rated Voltage (v) | Rated Current (A) | Overload Capacity | Starting Current | Insulation |
| DD862-4 | 2.0 | 220 | 1.5(6),2.5(10),5(20),3(12), 10(40),15(60),20(80),30(100) | 400% Ib | 0.5% Ib | AC voltage 2kV for 1 minute impulse voltage 6kV |
| DD862-2 | 3(6),5(10),2.5(5),10(20), 20(40),30(60),40(80) | 200% Ib |
We can provide you all kinds of electronic components including miniature circuit breaker, earth leakage circuit breaker, AC contactor, Power relay, etc. 
America
Russia
Spain